Cool your Home Naturally & Efficiently with a QuietCool Whole House Fan.

J Martin Indoor Air Quality, LLC offers clients a great way to cool your home without the high cost that comes with running your air conditioner. According to the Department of Energy, using a QuietCool Advanced Whole House Fan is the most cost-efficient way to cool your home. With easily customizable solutions to fit any home, including garage, attic, and roof fans, it is a must-have for ANY homeowner!

STL PRO 1.5
STL PRO 2.5
STL PRO 3.3
STL PRO 4.8
STL PRO 5.5
STL PRO 6.0
STL PRO 7.0
STL PRO 1.5

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: 66.7 Watts
  • Air Flow: 1479 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 740 SQFT
  • Number of Speeds: 1
  • Duct Diameter: 14″
  • Duct Length: 6ft.
  • Motor Head Diameter: 14 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 1.98 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 14 1/4″
  • Removable Grille Outside Dimension: 16″ x 16″
STL PRO 2.5

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: Hi: 157 Watts / Low: 82.3 Watts
  • Air Flow: Hi: 2541 CFM / Low: 2018 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 1280 SQFT
  • Number of Speeds: 2
  • Duct Diameter: 16″
  • Duct Length: 6ft.
  • Motor Head Diameter: 16 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 3.39 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 18 1/4″
  • Removable Grille Outside Dimension: 16″ x 20″
STL PRO 3.3

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: Hi: 157 Watts / Low: 82.3 Watts
  • Air Flow: Hi: 2541 CFM / Low: 2018 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 1280 SQFT
  • Number of Speeds: 2
  • Duct Diameter: 16″
  • Duct Length: 6ft.
  • Motor Head Diameter: 16 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 3.39 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 18 1/4″
  • Removable Grille Outside Dimension: 16″ x 20″
STL PRO 4.8

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: Hi: 408 Watts / Med: 225 Watts / Low: 73.9 Watts
  • Air Flow: Hi: 4280 CFM / Med: 3500 CFM / Low: 2361 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2140 SQFT
  • Number of Speeds: 3
  • Duct Diameter: 18″
  • Duct Length: 9ft.
  • Motor Head Diameter: 18 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer and Double 3-Way
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 5.71 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 30 1/4″
  • Removable Grille Outside Dimension: 16″ x 32″
STL PRO 5.5

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: Hi: 490 Watts / Med: 268 Watts / Low: 88 Watts
  • Air Flow: Hi: 5044 CFM / Med: 4238 CFM / Low: 2870 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2530 SQFT
  • Number of Speeds: 3
  • Duct Diameter: 20″
  • Duct Length: 9ft.
  • Motor Head Diameter: 20 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer and Double 3-Way
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 6.73 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 30 1/4″
  • Removable Grille Outside Dimension: 16″ x 32″
STL PRO 6.0

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: Hi: 462 Watts / Med: 210 Watts / Low: 113 Watts
  • Air Flow: Hi: 5587 CFM / Med: 4262 CFM / Low: 3428 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2800 SQFT
  • Number of Speeds: 3
  • Duct Diameter: 22″
  • Duct Length: 9ft.
  • Motor Head Diameter: 22 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer and Double 3-Way
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 7.45 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 36 1/4″
  • Removable Grille Outside Dimension: 16″ x 38″
STL PRO 7.0

Stealth Pro in Orange County

Product Specifications

  • Motor Voltage: 120 VAC, 60 Hz
  • Energy Use: Hi: 725 Watts / Med: 319 Watts / Low: 166 Watts
  • Air Flow: Hi: 6996 CFM / Med: 5448 CFM / Low: 4308 CFM
  • Recommended SQFT Coverage @2CFM per SQFT: Covers up to 3500 SQFT
  • Number of Speeds: 3
  • Duct Diameter: 24″
  • Duct Length: 9ft.
  • Motor Head Diameter: 24 1/2″
  • Motor Head Length: 13 1/2″
  • Dampers: Barometric Pressurized R5 Dampers
  • Controls: included 8 Hour Electronic Timer and Double 3-Way
  • Warranty: 15 years
  • Framing: None Required
  • Joist Cutting: None Required; fits 16″ or 24″ on center
  • Minimum Suggested Attic Venting: 9.33 SQFT net free area
  • Ceiling Rough Opening: 14 1/4″ x 36 1/4″
  • Removable Grille Outside Dimension: 16″ x 38″

Stealth Pro in Orange County

R5 Damper Box with Removable Grille

QuietCool’s damper system features barometric pressurized gravity dampers that prevent heat/cooling loss between the home and attic. Traditional whole house fans that have older style shutters offer zero R-Value. The removable egg‐crate grille is very easy to remove and clean. During the colder months of the year, a homeowner can also apply the R40 Winterized Kit option to seal the QuietCool damper box with R45 value.

Stealth Pro in Orange County

Wall Controls and Timers

Every QuietCool Trident Pro models include the standard manufacturer wall‐switch controls. This includes an Electronic 8‐Hour Countdown Timer and a single or multi-speed control switch (if applicable). Be sure to contact us if you have any questions about switches and timers for QuietCool whole house fans.


 

Hurry up! Contact Us Today And Get

SPECIAL DEALS!

Contact Us Now